Rotary Concentrators
Gasco supplies solutions to high volume low VOC concentration streams by
employing the principle of VOC concentration followed by Thermal Oxidation, .
Gasco utilises Rotary Concentration technology from Seibu Giken. Refer:
www.seibu-giken.co.jp
Seibu Giken VOC Concentrators have 30 years of technical background, honeycomb
processing, coating or impregnating various types of operative materials behind
them.
Seibu Giken VOC Concentrators are incorporated with the VOC absorbent rotor
which has several optional models and such absorbents as a hydrophobic zeolite,
an activated carbon and others are used either solitarily or in a mixture to be
coated on or impregnated into a calcined honeycomb matrix.
Low HC concentration stream is concentrated by a factor of 10-20:1 reducing or
eliminating the need for supplementary fuel in a TO or RTO. Gasco will design,
supply, install and commission a complete VOC abatement package.
Top: VOC Concentrator Rotor supplied for replacement.
Centre: VOC Concentrator Cassette. Air volume: 160,000 m3/hr.
VOC: IPA, Toluene, etc. Installed in Gravure printing factory.
Bottom: VOC Concentrator Unit. Air Volume: 33,000 m3/hr.